Soil Resistivity Survey Along a 62-Mile Pipeline Route, Lake Charles Area (2026)

We typically respond within one business day.

Project at a glanceDE-PRJ-8787

Location
Lake Charles, LA
Service
Soil resistivity
Client
Confidential

Soil Resistivity Survey Along a 62-Mile Pipeline Route, Lake Charles Area (2026)

In September 2026 we measured soil resistivity along the route of a planned pipeline of about 62 miles near Lake Charles, Louisiana. Client details are confidential.

Soil resistivity test leads laid out along a cleared right of way

Why measure before the pipe goes in

Soil resistivity is the first input to a cathodic protection design. Low resistivity means corrosive soil and a lower resistance path for CP current. It sets how much current the line will need, where anode beds can go and how far protection will spread. Measuring along the route before construction lets the designer place the CP system where the soil calls for it, instead of guessing from a few borings.

The fieldwork

The plan called for 14 test locations along the alignment. Three could not be reached, so we tested 11. Over three days we ran the Wenner four-electrode method of ASTM G57 at each site with a Fluke 1625-2 and a cable harness, at pin spacings of 2.5, 5, 7.5, 10, 15 and 20 feet. Where space allowed, the pin layout was turned 45 or 90 degrees and measured again to confirm the first set. From the average resistivities we calculated layer resistivities with the Barnes method, because averaging can hide a corrosive layer under a drier one.

What the route looks like

The sites fall into two groups. The upland sites, in grassy fields and pipeline easements, varied widely, from more than 11,000 ohm-cm near the surface at one site to a few hundred ohm-cm at others, generally dropping with depth. The wetland sites, with low grass near the surrounding water level, averaged roughly 90 to 200 ohm-cm, and some calculated layers were below 100 ohm-cm. On a scale where anything under 500 ohm-cm is severely corrosive, the route as a whole classifies as severely corrosive to ferrous metal.

What else matters

Resistivity is the main field indicator, but it is not the only one. pH, chemical content, soil type, aeration, anaerobic conditions and drainage also affect corrosion, and they are usually measured in the laboratory on samples taken during geotechnical drilling. Reading those results alongside the resistivity profile gives the CP designer a complete picture.

Soil testing for pipelines

The testing is described on our page for soil corrosivity analysis. Other work in the state is listed on our page for Louisiana.