Licensed Professional Engineers |
Search/

Request a free quote

Colorado Electrical and Corrosion Engineers

AC Interference Testing and Mitigation in Colorado

We typically respond within one business day.

Pipelines Near Power Lines and Electrified Rail

What AC interference does to a pipeline

When a buried pipeline runs alongside high-voltage transmission lines or electrified rail, the AC field induces voltage on the pipe. That causes two problems. Anyone who touches a test station, valve or other exposed appurtenance can get a shock from the touch voltage. And at small coating holidays, AC corrosion can attack the pipe even while the cathodic protection potentials look acceptable. Neither shows up until someone measures the AC.

A fault on the power line makes it worse for a short time: the induced voltage rises sharply, and a tower close to the pipe can push fault current into the soil around it, which can damage the coating and the pipe.

Diagram of a buried pipeline paralleling a transmission line, showing induced AC voltage and a test station

How a pipeline beside a transmission line picks up AC, and what to measure before it becomes a safety or corrosion problem.

Why Colorado corridors see it

As the Front Range grows, pipelines, transmission lines and rail get squeezed into the same narrow corridors, and new transmission projects keep adding sources. In the DJ Basin, gathering lines cross power line corridors again and again. Rocky, high-resistivity ground also makes mitigation grounding harder to get low, so designs have to be based on soil readings from the actual right-of-way. Our article on high-resistivity Rocky Mountain soils explains why.

What we do about it

  • Measure. We measure induced AC voltage and current on your structures in the field, along with your CP readings, as part of our interference testing practice.
  • Model. We work out which crossings and parallels drive the readings, and what happens under fault conditions on the power line.
  • Mitigate. Where the readings call for it, we design the mitigation: gradient control at test stations and valves, grounding along the line, and decoupling devices that pass AC to ground without draining the CP current. Designs are PE-stamped where required.
  • Confirm. A follow-up survey checks that the mitigation works, and the results go in your integrity file.

Our engineers are licensed Professional Engineers with active and past licensure in multiple states, and we work in Colorado from our Westcliffe office. Stepan V. Eero, M.S., P.E. is a NACE CP Specialist (CP4). The Colorado engineering services page lists our other work in the state, and our article on what causes cathodic protection interference covers DC interference.

Talking to us about your pipeline

  • Call (866) 621-6920 or write to us through the contact form, and mention any power lines or rail sharing the corridor. We typically respond within one business day.
  • You get a scoped proposal and a free quote up front. Our rate schedule is available on request.
  • Our licensed PEs supervise the surveys and the reports, which are PE-stamped where required.
  • We also have an office in Coldspring, Texas, and work in other states.

Frequently asked questions

What is AC interference on a pipeline?

Voltage and current induced on a buried pipeline by nearby high-voltage AC power lines or electrified rail. It can create a shock hazard at test stations and valves, and AC corrosion at coating holidays.

How do I know if my pipeline has a problem?

By measuring it. We read the AC pipe-to-soil voltage at test stations and appurtenances near power lines, and where needed install coupons to measure AC and DC current density, which shows the corrosion risk better than voltage alone.

What does AC mitigation usually involve?

Gradient control mats or wire at test stations and valves to limit touch voltage, grounding conductors along the pipeline to drain induced current, and decoupling devices that connect the pipe to that grounding for AC while blocking the DC cathodic protection current.

Will mitigation affect my cathodic protection?

It shouldn’t, if it is designed for it. Decoupling devices block DC, so the CP current stays on the pipe. We check the CP readings again after the mitigation is installed.

What should I send to get a quote?

Route maps, the power lines and rail that share the corridor, recent CP survey data and any AC readings you already have. Quotes are free.

Get your project started

We typically respond within one business day.

Request a free quoteor call (866) 621-6920