DCVG Coating Survey of About 93 Miles of New Pipeline for Its Operator, Central Texas (2020)

In April 2020 we started a DCVG coating survey for the operator of a new pipeline, beginning at the north end of the spread near Turnersville and working southeast. By June 5 the crew had walked about 93 miles and logged 62 indications.

Getting a usable signal

The new line already had galvanic anodes connected, and they held the pipe too negative to apply and hold a DCVG signal within the required limits. On the first day, with all anodes disconnected along about 20 miles, the pipe still read -1,400 mV; the next day, with about 45 miles disconnected, it read -1,250 mV. After that each day began by connecting a generator and a temporary rectifier, grounded to a metal culvert or to an unfinished rectifier groundbed. Typical settings gave -8.1 V on and -1.3 V off at the rectifier, or -10.4 V on and -1.2 V off. The two-person crew walked about 2 to 4 miles of pipe a day.

What the survey found

Each indication was graded by percent IR and recorded with its station, GPS position and time. Most were small: 33 were under 16 percent IR, 20 were between 16 and 35 percent, two were between 36 and 60 percent and seven were above 60 percent. Of the seven largest, two were galvanic anodes rather than coating holidays, one traced to damaged test leads and cleared after the leads were repaired, and two were noted as possibly caused by damaged wiring. Two indications at a road bore were checked again in May and the area was confirmed clear.

Reporting

We filed a daily report on the operator form with miles walked, anomalies found, the running total, potentials at the rectifier and the schedule, plus a running anomaly list for the whole spread.