Galvanic Cathodic Protection Design and Specification for a 30-Inch and 24-Inch Water Pipeline, Plano (2018)

A regional water district planned a 30-inch and 24-inch water pipeline in Plano and had not yet picked the pipe material. We prepared the galvanic cathodic protection design and specification so that either ductile iron or bar-wrapped concrete cylinder pipe could be bid, issuing the specification drafts between July and September 2018.

The test station plan

The schedule lists 15 test stations along the line. Eleven carry a pair of 32-pound magnesium anodes: two on the pipe itself, seven at 42-inch steel casings and two where the line passes through 48-inch liner plate. Three more sit at the tie-ins to existing 48-inch and 24-inch lines, and one is at a crossing with an existing gas line. Stations are post, vault or flush mounted to suit the location.

What the specification requires

The new pipe is isolated from existing lines, reinforcing steel, dissimilar metals and conduits, and every joint that is neither insulated nor welded is bonded with No. 2 copper wire. Anodes are high potential magnesium to ASTM® B843 in a backfill of 75 percent gypsum, 20 percent bentonite and 5 percent sodium sulfate. Test wires follow a color code for protected pipe, unprotected pipe, casings and foreign pipe. Foreign line crossings get coupons to NACE SP0104 with IR free monitoring tubes, and insulating flange kits use G-10 epoxy glass gaskets, sleeves and washers.

Testing is built into the work. The contractor corrosion engineer or technician tests wire connections, insulating joints, casing insulators and joint bonds before and after backfill, then submits a system check-out report certifying that the criteria are met, together with record drawings.