Tank-Farm Corrosion Assessment, Tampa (2024)

We typically respond within one business day.

Project at a glanceDE-PRJ-8119

Location
Tampa, FL
Service
Tank integrity
Client
Confidential

Tank-Farm Corrosion Assessment, Tampa (2024)

We did a tank-farm corrosion assessment in Tampa, Florida, in 2024. Client details are confidential.

External corrosion on industrial pipe

External corrosion on industrial pipe. A tank farm assessment records corrosion like this and grades how far it has gone.

Deciding where to start in a yard full of tanks

There’s a lot of steel in a tank farm, and no two of the tanks age the same way. Shells and roofs weather in the open air. The bottoms rest on a foundation, where the owner can’t see what’s going on. Whatever a tank holds sets up its own conditions on the inside. Tampa is a coastal city, so the external coatings also have to stand up to salt-laden air and long stretches of high humidity. Owners rarely wonder whether there’s corrosion somewhere on the property. They want to know which tanks to deal with first, and what kind of work each one needs.

How a storage tank corrodes

A sound assessment looks at every way the tank can corrode. On the outside, that means the coatings on the shells, roofs and appurtenances. Then there’s the soil side of the tank bottom, which is a real risk because nobody can see it. If the bottoms have cathodic protection, structure-to-soil potential readings show whether the protected steel is picking up the current it needs at coating defects and bare spots. Internal corrosion is a separate question. It comes down to what the tank stores and whether water can settle on the floor.

On the coast, the atmosphere gets its own line in the assessment. Chlorides and a long time of wetness speed up attack on any exposed steel, so coating condition counts for more here than it would inland. In the end it all goes into a ranking of which tanks, and which surfaces on them, need the most attention. That tells the owner where to put the inspection and maintenance budget.

Rusted pipe stub with an uneven corroded top rising from a bolted flange, beside two upright rods and a corrugated hose

Corroded pipe stub at a bolted flange connection. Fittings and connections like this are part of a tank farm assessment. Formal tank inspection is a separate job with a narrower scope.

How this fits with the API and AWWA® standards

Most owners of aboveground storage tanks already work under a formal inspection program. For a lot of petroleum tanks, that’s API® 653. It covers in-service and out-of-service inspections, thickness measurements, and the evaluation and repair of shells, bottoms and roofs. It also sets how often those inspections come around. Cathodic protection of tank bottoms has its own document, API® RP 651, and internal linings are in API® RP 652. Water storage tanks come from a different family of standards. For them, AWWA® D104 covers impressed current protection of the submerged interior surfaces.

A corrosion assessment doesn’t replace any of that, but it does make the formal program more efficient. Inspections and thickness surveys are expensive and they disrupt operations, so an owner with a lot of tanks has to decide which ones go to the front of the line. A field assessment gives them that order. It grades the external coatings and looks at the soil side, including any cathodic protection under the bottoms, and it weighs the exposure each tank sees. Some of what it turns up shouldn’t wait for the next scheduled inspection, like failed coating on an appurtenance or water collecting against a chime. A protection system that has stopped delivering current can’t wait either.

The owner ends up with a prioritized list, tied to specific findings, that they can budget from. Some tanks need coating work and some need their cathodic protection evaluated or repaired. Others should move up the inspection schedule. Our tank and pipeline integrity assessment services pick up from there.

At the Tampa tank farm

Our team did the assessment in the field. We looked at the corrosion conditions affecting the tanks and documented what we saw across the facility. Cathodic protection staff with AMPP® (NACE) certification handled the corrosion-control parts of the work, and a licensed Professional Engineer supervised the assessment and the recommendations that came out of it. The findings went to the owner as a prioritized report they could work through tank by tank. We didn’t boil the whole farm down to one pass-or-fail grade.

Catching metal loss while it’s cheap to fix

Corrosion left alone for years can mean a bottom repair or a product release down the road, and it can turn into a regulatory problem. Found early, the same metal loss costs little to deal with. A structured corrosion assessment tells the owner where to step in before it gets that far, and which tanks to spend on first. Our corrosion engineering consulting practice does this kind of work for tank and terminal owners. More of our projects from around the state are on our Florida page.

Get your project started

We typically respond within one business day.