Selected Projects

Pipeline Coating Surveys, Orla and Pecos, and Cathodic Protection Designs, Laredo and Bryan (2024-2025)

We typically respond within one business day.

Project at a glanceDE-PRJ-8126

Location
Permian Basin and South Texas
Service
DCVG, CP design
Client
Confidential

Pipeline Coating Surveys, Orla and Pecos, and Cathodic Protection Designs, Laredo and Bryan (2024-2025)

Our corrosion team ran pipeline coating surveys in the Permian Basin, near Orla and Pecos, between 2024 and 2025. In the same period we designed cathodic protection for assets in Laredo and Bryan. We don’t share client details.

Worker on a large buried pipe in an open excavation

A buried line uncovered in a trench. The coating is the pipe’s main defense, and a survey shows the operator where it has stopped working.

Two kinds of corrosion work

A coating survey and a cathodic protection design come at the same problem from opposite ends. The survey starts with pipe already in the ground and looks for where its coating has failed. The design starts with a structure and works out how much current it needs and where to supply it from. It also says how long the supply must last. The sites weren’t alike either. The Permian gathering and transmission lines run through remote rights of way, and a crew covers long distances between access points. The South Texas designs had to account for their own soil conditions and the structures around them. In both cases the answers come from measurements taken on site.

What the DCVG probes pick up

It’s easy to explain direct current voltage gradient (DCVG) surveying backwards, so start with where the current goes. On a buried pipeline under cathodic protection, the pipe is the cathode. Protective current flows out of the anode bed and through the soil to the pipe. The coating is an insulator, so the current can only reach the steel where the coating is damaged. At each defect, current from the surrounding soil funnels in toward the bare steel, and that produces a voltage gradient you can measure in the soil right above it.

In the field, the crew switches the protective current off and on at a fixed cycle, so the gradient pulses in a rhythm they can recognize. Then they walk the line with two probes touching the soil and read the voltage difference between them. Over sound coating the reading stays small. It grows as they get closer to a defect, and the gradient points the way, so the crew can walk in on it and mark the spot closely. Each defect’s severity is then expressed as a percentage of the total pipe-to-remote-earth voltage drop at that spot. That lets you rank defects against each other instead of just counting them, and the ranking is the useful part. An operator with a long list of anomalies needs to know which three to dig up first.

Test tubes of orange liquid in a white rack and a graduated glass flask, on pale dry ground with cracked earth behind

Test tubes and a graduated flask on dry, open ground. The numbers a design runs on come from the site. Soil resistivity controls the anode-to-earth resistance and how big the groundbed has to be, and the area of bare or poorly coated steel sets how much current the system has to deliver.

Sizing a cathodic protection system

A design starts with the structure. The first things to pin down are what it’s made of, how much of its surface is exposed to the electrolyte, how good the coating is and how it will age, and whether the structure is electrically continuous. Soil resistivity measurements tell us how easily current will move through the soil and where an anode bed can reasonably go. Those inputs give us a current requirement, which drives the choices that define the system. If the requirement is modest and the soil is favorable, galvanic anodes will do. A larger requirement, or soil with high resistivity, calls for an impressed current system with a rectifier.

The details come next, and they decide whether the design still works once a construction crew gets hold of it. That means the anode type, spacing and depth, and the cable sizes and routes. The rectifier needs enough spare capacity to keep up as the coating degrades over its service life. The protected structure has to be electrically isolated from foreign structures. Test stations go where a technician can get to them and take the readings the system will be judged by. A licensed Professional Engineer seals the package.

The work near Orla, Pecos, Laredo and Bryan

Out in the Permian, the surveys covered pipeline segments near Orla and Pecos. The fieldwork was done by our AMPP® (NACE) certified cathodic protection personnel. They located and graded the coating anomalies, and we reported the results so the operator could decide which excavations and repairs to do first. Laredo and Bryan were design jobs. Licensed Professional Engineers produced those cathodic protection designs and delivered them as engineering packages.

How coating and cathodic protection split the work

The two are meant to be used together. The coating does most of the work, and cathodic protection covers the spots it misses. A survey that grades defects shows an operator where the coating has stopped doing its share. A design says how much protection the rest of the system has to supply. Whichever one you need, start with our DCVG survey services or our cathodic protection design services. If you’re not sure DCVG suits your line, our article on the difference between ACVG and DCVG surveys explains when to use each.

Get your project started

We typically respond within one business day.

Request a free quoteor call (866) 621-6920