Corrosion and CP
Cathodic Protection in the San Antonio Area
Our work on cathodic protection in the San Antonio area has been on water infrastructure: four new transmission lines and the yard piping at two pump stations in San Antonio, and a planned water line in New Braunfels. We have also tested the grounding at a packaging plant near the city.
We typically respond within one business day.
Area at a glanceDE-LOC-SAT-C
- Area
- San Antonio and New Braunfels
- Served from
- Coldspring, TX office and engineering lab
- Practice
- Corrosion and CP
- Write-ups in the area
- 4
- Multi-site or nearby
- 4
- Licensure
- Licensed Professional Engineers with active and past licensure in multiple states
From fat clay to limestone
The four transmission lines cross ground that ranges from fat clay to solid limestone. Along them we ran Wenner four-pin tests at 21 locations, and layer resistivities ranged from 376 ohm-cm in fat clay to more than 300,000 ohm-cm in limestone at the terminal. Laboratory tests on boring samples found sulfates up to 3,220 ppm along the clay route, enough that we suggested sulfate-resistant Type V cement for concrete there.
The limestone needed its own reasoning. Undisturbed rock is highly resistive, but crushed rock used as trench backfill has lower resistivity and more oxygen, so pipe laid open cut in limestone still sees moderately corrosive conditions. In New Braunfels the north end of the route sits on limestone while most of it is fat clay, lean clay and clayey gravel, and the lowest layer measured 321 ohm-cm.
Tunnels, mixed metals and the aquifer
Large water projects mix materials. On one 54-inch line, 170 feet of coated steel laid open cut joins about 10,500 feet of bare steel set in grout. That pairing forms a mixed-metal cell with a driving voltage that can reach about 0.5 V, and the small defects in the coating become its anodes. Resistivity varied too much along the routes for sacrificial anodes, so the 36, 48 and 54-inch lines got impressed current from deep anode wells, and the 24-inch line, mostly plastic, got monitoring only. Part of the alignment lies over the recharge and transition zones of the Edwards Aquifer, so we noted that the wells would likely need permits from the aquifer authority.
Testing what was built
At one of the pump stations the specifications required a corrosion engineer to witness the CP testing, and we took that over from another engineer in 2023. We watched the crew open every test station and install GPS-synchronized interrupters on every anode station. Several deficiencies remained, and by our return in 2024 they had been resolved.
In New Braunfels we also noted that overhead distribution lines run along the whole alignment, and unbalanced loads on them can induce AC on a metallic pipeline.
Grounding near San Antonio
At a corrugated packaging plant near San Antonio we measured the ground path from the building ground rod to nearly every piece of equipment, about 150 readings, and none failed. Four readings above 5 ohms were flagged as worth watching, and we recommended repeating the survey about once a year.

Project write-ups
Write-ups from the San Antonio area
A few examples from over 1,100 completed projects. Client details stay confidential.
Corrosion and CP
CP Design for Four Water Transmission Lines, San Antonio
Corrosion and CP
Pump Station Yard Piping CP Design and Testing, San Antonio
Corrosion and CP
Soil Corrosivity Study for a Water Line, New Braunfels
Electrical power
Point-to-Point Grounding Survey at a Packaging Plant, San Antonio Area
Multi-site and nearby write-ups
- RV Park Service and Feeder Sizing in Dayton, Strawn and San AntonioDayton, Strawn and San Antonio, TX
- Soil Resistivity Tests for Grounding Design, South TexasCotulla, Pleasanton and Victoria, TX
- Soil Resistivity Tests for Grounding Design, Comfort and MidlothianComfort and Midlothian, TX
- Brewery Grounding Survey and Power Quality MonitoringSouth Central Texas
Services
What we offer here
- Soil Corrosivity AnalysisWenner four-pin testing and a corrosivity rating for the route.
- Cathodic Protection DesignGalvanic and impressed current systems, PE-stamped where required.
- Start-Up and CommissioningConstruction visits, start-up testing and acceptance readings.
- Cathodic Protection Potential SurveysAnnual and compliance surveys with interrupted readings.
- Ground Testing and CommissioningFall-of-potential, point-to-point, Ufer and soil resistivity tests.
Who does the work
Served from Coldspring, Texas
San Antonio work is run from our office and engineering lab in Coldspring, Texas.
Our corrosion engineers include Stepan V. Eero, P.E., an AMPP (formerly NACE) CP4 Cathodic Protection Specialist, and Brian J. Brackensick, P.E., an AMPP CP3 Cathodic Protection Technologist. Designs are PE-stamped where required.
Request a free quote for your project
We typically respond within one business day.