CP Test Station Readings: On, Instant-Off and IR Drop

We typically respond within one business day.

A cathodic protection survey reads the pipe-to-soil potential at test stations along a pipeline or around a tank, against a copper/copper sulfate reference electrode. While the rectifier is on, the reading includes a voltage drop in the soil (the IR drop), so it looks more protective than the steel really is. An interrupted survey switches the current off for a moment and reads the instant-off potential, which has the IR drop removed.

The explainer below shows that reading at one test station. Change the rectifier current or the moment the reading is taken, add a galvanic anode that cannot be switched off, or read a coupon instead of the pipe, and see how the on reading, the instant-off reading and the two criteria it uses from AMPP® SP0169 (−850 mV instant-off and 100 mV of polarization) respond.

Test station Illustrative

On, instant-off and IR drop at a test station

An interrupter switches the rectifier off for a moment. Read just after switch-off, the instant-off potential has the IR drop removed. Change the current, when the reading is taken, or measure a coupon instead of the pipe.

Fig. 1Interrupted pipe-to-soil potential · one test stationAMPP® SP0169
Interrupted pipe-to-soil potential at a test station A coated steel pipe with a rectifier and interrupter, an anode, a test station, a coupon, a voltmeter and a copper/copper sulfate reference electrode. Below it, the potential over time as the current is switched off for one second, with the native potential, the native minus 100 mV line and the minus 850 mV criterion. A marker shows when the instant-off reading is taken. The values are listed beside the figure. Rectifier Anode Coated steel pipe Interrupter Coupon Galvanic anode Instant-off −0.787 V CSE −0.6−0.8−1.0−1.200.20.40.60.81.0 V vs CSESeconds after switch-off OffOnOn native native − 100 mV −850 mV
Potential When the reading is taken IR drop
Illustrative model, not field data (native −0.620 V CSE). Which criterion applies, how IR drop is considered and when readings are taken are decided for each system by a qualified CP engineer.
What is measured
3.00 A
200 ms
On reading−0.913 V
Instant-off−0.787 V
IR drop126 mV
Polarization167 mV
−850 mV instant-off Not met
100 mV polarization Met

Neither criterion is met: polarization is under 100 mV and the instant-off reading is short of −850 mV.

The 100 mV polarization criterion is met. The instant-off reading is still short of −850 mV.

The on reading looks protected, but part of it is IR drop in the soil. Instant-off is short of −850 mV; the 100 mV criterion is met.

Both are met: instant-off is more negative than −850 mV and polarization is over 100 mV.

Too early: the switching spike is still in this reading, so it is not yet the polarized potential.

The anode’s current is not interrupted, so this instant-off still holds IR drop and looks more protected than the steel is. A coupon reading avoids this.

Late: the steel has begun to depolarize, so this reading is less negative than the polarized potential.

Taken after the switching spike and before noticeable depolarization: a fair instant-off reading.

The coupon is disconnected, so no current reaches it through the soil: its off reading has no IR drop, even with an anode connected.

See a whole close interval survey

How the explainer works

  • It is an illustrative model of one coated steel pipe, not field data. The pipe’s native potential in the model is −0.620 V against a copper/copper sulfate electrode (CSE).
  • The on reading is taken with the rectifier running. The instant-off reading is taken at the moment you set after the interrupter switches the rectifier off.
  • IR drop is the on reading minus the instant-off reading. Polarization is the instant-off reading minus the native potential. Both are worked out from the readings as shown, in whole millivolts, the way a surveyor would work them out from a field sheet.
  • The two criteria are the ones the explainer names from AMPP® SP0169: an instant-off potential of −850 mV or more negative, and at least 100 mV of polarization.
  • The note under the readings says when a reading is taken too early (the switching spike is still in it), too late (the pipe has started to depolarize), with current from a bonded galvanic anode still in it, or on a coupon.
  • The same model runs the CP readings section of our cathodic protection potential surveys page.

Which criterion applies, how IR drop is considered and when readings are taken are decided for each system by a qualified CP engineer. This page has its own address, so a course page or a survey report can link straight to it.