Soil Testing and Galvanic Cathodic Protection Design for Two Water Line Replacements, Houston (2015)

In 2015 we prepared the corrosion protection for two municipal water line replacements in Houston: a 24-inch line and a 30- and 36-inch line. Both designs use zinc anodes, and the soil on the 24-inch route explains why protection was needed.

The soil

On October 15, 2015 we ran Wenner four-pin tests along the 24-inch route for a pipe depth of 8 to 14 feet, and four samples from the borings went to a laboratory. Three were clay, two of them fat clay, and one was silt. As received they measured 640 to 2,400 ohm-cm, and saturated 560 to 2,400 ohm-cm, with the fat clays the lowest. Soil that conductive is aggressive to buried iron and steel.

The 24-inch design

At the 60 percent design the line had 13 flush-mounted test stations. Four are anode stations, each with eight 60-pound zinc anodes. Five are isolation stations, where insulating flanges separate the new pipe from the existing 24-inch line at the tie-ins and from an existing aerial crossing. The remaining four test the steel casings at cased crossings, one of them also at a foreign line.

The 30- and 36-inch design

On the larger line the design puts a flush-mounted anode test station with ten zinc anodes at each of seven new butterfly valves, six on the 36-inch section and one on the 30-inch section.