Licensed Professional Engineers |
Search/

Request a free quote

Free tool screening estimate

Corrosion Rate Converter: mpy, mm/y, mdd and Mass Loss

Converts a corrosion rate between mm/y, µm/y, mpy, in/y and the mass units mdd, g/(m²·d) and g/(m²·y), or works it out from a coupon's mass loss.

Tool referenceDE-TOOL-10857

Method
ASTM® G1 rate equation; 1 in = 25.4 mm
Units
mm/y, µm/y, mpy, in/y, mdd, g/(m²·d), g/(m²·y)
Output
The rate in every unit

A corrosion rate converts between units with two facts: an inch is 25.4 mm (1 mpy = 0.0254 mm/y), and a mass rate becomes a thickness rate when you divide by the metal’s density. From a coupon, the ASTM® G1 form gives the rate in mm/y as 8.76 × 10⁴ × mass loss ÷ (area × hours × density), with grams, cm², hours and g/cm³.

Corrosion rate converter and mass loss calculator

Convert a corrosion rate between mm/y, µm/y, mpy, in/y and the mass units mdd, g/(m²·d) and g/(m²·y), or work out the rate from a coupon's mass loss, area and exposure time. The answer updates as you type and shows every unit at once.

The converter needs JavaScript®. The formulas and the densities it uses are on this page.

Quick start Fills in the form. Change anything after.

What you have
Start from

The coupon mass before exposure minus its mass after cleaning off the corrosion products.

The total surface area the environment reached, both faces and the edges of a flat coupon.

Metal

Pure metals, densities from PubChem. For an alloy, choose Other and enter its density.

Converts thickness to mass. Use the density of the alloy you tested, not of its main element, when you know it.

Result

0.193 mm/y, or 7.60 mpy

A mass loss of 0.25 g from 20 cm² over 30 days is 0.193 mm/y, or 7.60 mpy.

The mass units use the density of iron, 7.874 g/cm³ (PubChem).

The rate assumes the metal was lost evenly over the whole area. A report from the Savannah River National Laboratory notes that rates from mass loss may substantially underestimate the depth of localized corrosion such as pitting.

mm/y
0.193
mpy
7.60
mdd
41.7

A rate from mass loss is an average over the whole surface. Pits and local attack go deeper than it shows. See corrosion engineering, or ask an engineer.

Aligned unit scales: the same rate on every unitYour rate, 0.193 mm/y, is 7.60 mpy and 41.7 mdd.mm/y10⁻²1µm/y10¹10³mpy10⁻¹10¹in/y10⁻⁴10⁻²mdd110²g/(m²·d)10⁻¹10¹g/(m²·y)10²10⁴
Log scales. The vertical line is your rate; the powers of ten of each unit fall at different places, which is the conversion.

The same rate in every unit

UnitValueFrom mm/y
Millimeters per year (mm/y)0.193×1
Micrometers per year (µm/y)193×1,000
Mils per year (mpy)7.60÷0.0254
Inches per year (in/y)0.00760÷25.4
Milligrams per square decimeter per day (mdd)41.7×10 D ÷0.365
Grams per square meter per day, g/(m²·d)4.17×D ÷0.365
Grams per square meter per year, g/(m²·y)1,521×365 D ÷0.365
Full results and steps
Mass loss0.250 g
Area20.0 cm²
Exposure720 h (30.0 days)
Mass loss per area125 g/m²
Density7.874 g/cm³
mm/y0.193
  1. Rate = 8.76 × 10⁴ × W ÷ (A × T × D) = 8.76 × 10⁴ × 0.250 ÷ (20.0 × 720 × 7.874) = 0.193 mm/y (W in g, A in cm², T in h, D in g/cm³; 8.76 × 10⁴ is 10 mm per cm times 8,760 hours a year).
  2. mpy = mm/y ÷ 0.0254 (1 mil = 0.001 in = 0.0254 mm): 0.193 ÷ 0.0254 = 7.60 mpy.
  3. g/(m²·d) = D × mm/y ÷ 0.365 = 7.874 × 0.193 ÷ 0.365 = 4.17; mdd = 10 × g/(m²·d) = 41.7.

Coupon data or a corrosion failure to review?

Dreiym's licensed Professional Engineers review corrosion monitoring data and investigate corrosion failures.

Assumptions and limits

Assumptions: uniform loss over the stated area; the mass loss is after the corrosion products were cleaned off; a year of 365 days (8,760 hours) for every unit.

What this does not do: it does not measure pitting or other local attack, correct for the metal lost while cleaning, or predict a future rate.

Screening tool: For education and planning. Not a corrosion assessment, and not a substitute for a licensed engineer's review.

How the calculation works
  • Mass loss to rate (ASTM® G1 form): rate in mm/y = 8.76 × 10⁴ × W ÷ (A × T × D), with W in g, A in cm², T in h and D in g/cm³.
  • Thickness units: 1 in = 25.4 mm and 1 in = 1,000 mils, so mpy = mm/y ÷ 0.0254 and in/y = mm/y ÷ 25.4.
  • Mass units need the density: g/(m²·d) = D × mm/y ÷ 0.365; mdd = 10 × g/(m²·d); g/(m²·y) = 365 × g/(m²·d).
Sources

Sources: ASTM® G1 rate equation and constant as quoted in Anuar et al., IJAME 16(1), 2019, Eq. (1), and in SRNL-STI-2018-00038 Rev. 1 (Savannah River National Laboratory), Eq. 1; FHWA-HRT-09-044 (2009), Appendix (1 in = 25.4 mm; 1,000 mils); PubChem periodic table (NIH), densities of the pure elements, read 19 November 2026.

Cite or share this tool

Dreiym Engineering. Corrosion rate converter. Method: ASTM® G1 rate equation (as quoted in SRNL-STI-2018-00038); densities from PubChem. https://www.dreiym.com/corrosion-rate-converter/

Instructors and shops are welcome to link to this tool or put its address on a handout. It is free, needs no sign-up and works on a phone.

How to use the converter

Start from a coupon’s mass loss, or from a rate you already have, and pick the metal. The result shows the rate in every unit, and the aligned scales show where each unit’s powers of ten fall for the same rate. Mass units (mdd and grams per square meter) change with the density; thickness units do not.

How to work out a corrosion rate from a coupon

  1. Weigh the coupon. Record its mass before exposure and again after the corrosion products are cleaned off; the difference is the mass loss W.
  2. Measure the exposed area. Add up every face and edge the environment reached, in cm² (A).
  3. Note the exposure time. In hours (T): 30 days is 720 hours.
  4. Find the density. In g/cm³ (D), for the alloy tested when you know it.
  5. Apply the ASTM® G1 form. Rate in mm/y = 8.76 × 10⁴ × W ÷ (A × T × D). Divide by 0.0254 for mpy.

Worked example

A coupon loses 0.250 g from 20 cm² in 30 days (720 hours), and is taken as pure iron, 7.874 g/cm³ (PubChem). The rate is 8.76 × 10⁴ × 0.250 ÷ (20 × 720 × 7.874) = 0.193 mm/y. In mpy, 0.193 ÷ 0.0254 = 7.60 mpy. In mdd, the same loss is 250 mg ÷ 0.2 dm² ÷ 30 days = 41.7 mdd, which the converter gives from the thickness rate and the density.

Where the constants come from

  • 8.76 × 10⁴. The ASTM® G1 constant for mm/y with grams, cm², hours and g/cm³, as quoted in two free reports. It is 10 mm per cm times 8,760 hours in a 365-day year.
  • 0.0254. 1 in = 25.4 mm and 1 in = 1,000 mils, so one mil is 0.0254 mm (FHWA-HRT-09-044).
  • 0.365. A loss of 1 g/m² of a metal of density D is 1/D micrometers thick; over 365 days, g/(m²·d) = D × mm/y ÷ 0.365.
  • 10. 1 m² is 100 dm² and 1 g is 1,000 mg, so 1 g/(m²·d) = 10 mdd.

A rate from mass loss is the average over the whole surface. The Savannah River National Laboratory report used below notes that rates calculated from mass loss may substantially underestimate the depth of localized corrosion such as pitting; our article on pitting corrosion explains why.

Verified against

Cases from free government reports, with the value printed in the source and the converter’s value. The unit tests run every row.

Published cases and the converter

CaseSourceConverterResult
SRNL coupon BP-2C: 0.0101 mm/y to mpy0.400.398Agrees to the 2 decimals printed
SRNL coupon BP-3: 0.0096 mm/y to mpy0.380.378Agrees to the 2 decimals printed
SRNL coupon BP-3C: 0.0122 mm/y to mpy0.480.480Agrees to the 2 decimals printed
SRNL coupon BP-4: 0.00848 mm/y to mpy0.330.334Agrees to the 2 decimals printed
All 16 SRNL coupons in Table 30.23 to 0.92 mpyEach within 0.005 mpyAgrees
Sandia coupon KIT-F1: 0.056 g/(m²·d), density 10.21 g/cm³, to µm/y2.002.00Agrees within the rounding of the printed g/(m²·d)
Sandia coupon KIT-F2: 0.218 g/(m²·d), density 10.03 g/cm³, to µm/y7.907.93Differs by 0.4 %, more than the rounding of the printed columns explains
Sandia coupon KIT-F3: 0.098 g/(m²·d), density 10.12 g/cm³, to µm/y3.513.53Differs by 0.7 %, more than the rounding of the printed columns explains
Sandia coupon KIT-F4: 0.0063 g/(m²·d), density 11.2 g/cm³, to µm/y0.200.21Agrees within the rounding of the printed g/(m²·d)
Sandia coupon KIT-F5: 0.016 g/(m²·d), density 11.16 g/cm³, to µm/y0.510.52Agrees within the rounding of the printed g/(m²·d)
Sandia coupon KIT-F6: 0.025 g/(m²·d), density 11.17 g/cm³, to µm/y0.820.82Agrees within the rounding of the printed g/(m²·d)
ASTM® G1 constant: 1 g, 1 cm², 1 h, 1 g/cm³8.76 × 10⁴ mm/y8.76 × 10⁴ mm/ySame equation

The two Sandia rows that differ come from the report itself: its µm/y and g/(m²·d) columns for those coupons do not match each other at the densities in its Table 5. We show the difference rather than adjust anything.

Method and sources

  1. L. Anuar and others, Development of Proving Ground Field Test for Establishment of Vehicle Accelerated Corrosion Test Procedure in Malaysia, IJAME 16(1), March 2019, Eq. (1): the ASTM® G1 rate equation with K = 8.76 × 10⁴ for mm/y.
  2. Savannah River National Laboratory, E-Area Corrosion Coupon Recovery and Evaluation, SRNL-STI-2018-00038 Rev. 1: Equation 1 from ASTM® G1-03 and Table 3 (16 coupons in mm/y and mpy).
  3. Sandia National Laboratories, Graphite Steel and Chromium-Nickel Steel Corrosion: Solution Flow-Through Corrosion Experiments, SAND2019-13627R: Equation [2] (the same rate equation with mg) and Tables 5 and 9.
  4. Federal Highway Administration, FHWA-HRT-09-044, Appendix, October 2009: 1 in = 25.4 mm; 1 in = 1,000 mils.
  5. PubChem periodic table (National Library of Medicine), densities, read November 19, 2026: iron 7.874, copper 8.933, zinc 7.134, aluminum 2.70, nickel 8.912, titanium 4.5, magnesium 1.74, lead 11.342, tin 7.287 and chromium 7.15 g/cm³.

Licence notes: the SRNL, Sandia, FHWA and PubChem sources are US government works; the IJAME article is free to read. ASTM® G1 itself is sold by ASTM® International and was not read; the page uses only the equation and constant as the free reports quote them. Numbers are restated with citations; no text or tables are copied.

Related: corrosion that varies over a structure is covered in our articles on corrosion rates in coastal structures and corrosion testing; for atmospheric exposure, see the ISO 9223 corrosivity category tool.

Frequently asked questions

How do you convert mpy to mm/y?

Multiply by 0.0254: one mil is 0.001 in and an inch is 25.4 mm. 5 mpy is 0.127 mm/y. To go back, divide mm/y by 0.0254.

Why does converting to mdd need the density?

mdd is a mass loss per area per day, and mm/y is a thickness loss per year. The density links mass to thickness, so the same mm/y is a larger mdd for a denser metal.

What is the ASTM® G1 corrosion rate formula?

Rate = K × W ÷ (A × T × D), with W the mass loss in grams, A the area in cm², T the time in hours and D the density in g/cm³. K is 8.76 × 10⁴ for mm/y.

Does a rate from mass loss show pitting?

No. It averages the loss over the whole area. A Savannah River National Laboratory report notes that such rates may substantially underestimate the depth of localized corrosion such as pitting.

Need more than a screening estimate?

We typically respond within one business day.

Request a free quoteor call (866) 621-6920