Tool referenceDE-TOOL-8046
- Calculated on
- Our server
- Solves
- DC, AC, transient and logic
- Includes
- Thévenin and Norton equivalents, a scope and DigiMin
A free online circuit solver. Draw a circuit the way an engineer would: drop resistors, capacitors, inductors, switches, op-amps, diodes, LEDs, transistors, transformers, and DC, AC or three-phase sources onto the canvas, wire them into any topology you like, and the solver computes every node voltage, branch current, and power dissipation as you edit, finds the Thévenin equivalent between any two nodes, and plots voltage and current over time. Logic gates, flip-flops and counters run beside them, with truth tables and a timing diagram, and DigiMin, a logic minimizer, turns a truth table into its simplest circuit. Built by the licensed Professional Engineers at Dreiym Engineering.
Loading the simulator…
Worked example
How to solve a circuit
Solving a circuit means finding the voltage at every node and the current in every branch. The example in the figure, a 12 V source driving R1 in series with R2 and R3 in parallel, takes six steps by hand. The simulator does the same work for any circuit you draw, as you draw it.
- Label the nodes. Choose one node as ground, the 0 V reference. Here the bottom wire is ground, and node A is where R1 meets R2 and R3.
- Combine the parallel resistors. R2 and R3 share both ends, so together they act as one resistor of 3 kΩ × 6 kΩ / (3 kΩ + 6 kΩ) = 2 kΩ.
- Combine the series resistors. All of the source current passes through R1, so the source sees 1 kΩ + 2 kΩ = 3 kΩ.
- Apply Ohm’s law to the whole circuit. I = V / R = 12 V / 3 kΩ = 4 mA leaves the source and flows through R1.
- Work back to the node voltages. R1 drops 4 mA × 1 kΩ = 4 V, so node A sits at 12 V − 4 V = 8 V.
- Find the branch currents. R2 carries 8 V / 3 kΩ = 2.67 mA and R3 carries 8 V / 6 kΩ = 1.33 mA. Together they make the 4 mA in R1, as Kirchhoff’s current law requires.
Check the power. The source delivers 12 V × 4 mA = 48 mW, and the resistors use 16 mW + 21.3 mW + 10.7 mW = 48 mW.
Thévenin equivalent
Seen from R3, the rest of the circuit behaves like one source behind one resistor. Remove R3, and node A sits at 12 V × 3 kΩ / (1 kΩ + 3 kΩ) = 9 V. Replace the source with a wire, and the resistance looking back into node A is 1 kΩ in parallel with 3 kΩ, or 750 Ω. So R3 draws 9 V / (750 Ω + 6 kΩ) = 1.33 mA, the same answer as step 6. In the simulator, the Thévenin tool finds this pair between any two nodes you pick.
Check it in the simulator
Open this circuit and the results table lists every node voltage, branch current and power. Change a value and the whole circuit solves again. Networks that series and parallel rules cannot reduce, such as a bridge, solve the same way, because the simulator writes Kirchhoff’s current law at every node (nodal analysis) instead of combining resistors.
Schematic: the source V1 feeds R1 along the top wire to node A; R2 and R3 run from node A down to the ground wire. Node A is at 8.00 V, 4.00 mA flows through R1, 2.67 mA through R2 and 1.33 mA through R3.
| Total resistance | 3 kΩ |
|---|---|
| Current in R1 | 4.00 mA |
| Voltage at node A | 8.00 V |
| Current in R2 | 2.67 mA |
| Current in R3 | 1.33 mA |
| Thévenin equivalent seen by R3 | 9 V behind 750 Ω |
How the Circuit Solver Works
Every number above comes from the three laws that anchor the first circuits course in an electrical engineering degree:
- Ohm's law. V = I × R. Voltage equals current times resistance; fix any two and the third is decided.
- Kirchhoff's current law (KCL). The currents into any node sum to zero: charge does not pile up. This is the law the solver writes down at every node of your drawing.
- Kirchhoff's voltage law (KVL). The voltage drops around any closed loop sum to zero. Each source in your drawing contributes its KVL constraint, and the node voltages the solver returns satisfy it around every loop automatically.
Those equations are assembled into a matrix (modified nodal analysis, the same formulation inside professional circuit simulators) and solved by Gaussian elimination on every edit. The series and parallel formulas taught first, Rtotal = R1 + R2 + … in series and 1/Rtotal = 1/R1 + 1/R2 + … in parallel, are special cases the solver reproduces exactly; but because it works from KCL and KVL directly, it also handles networks those shortcuts cannot reduce, like the Wheatstone bridge in the examples, whose detector R5 is neither in series nor in parallel with any other part.
Power follows from the same variables: P = V × I = I²R = V²/R. Power is the number that turns into heat, which is why each resistor carries a wattage rating and flags itself when its dissipation goes past that rating. Select a resistor and the panel also shows its color-band marking, the four or five bands that would be printed on the physical part, including the gold, silver, or brown tolerance band.
Op-amps join the same equations, one more per op-amp. Each is a finite-gain amplifier: its output, measured from the ground symbol, is the voltage between its inputs times an open-loop gain (106 unless you change it), up to output limits you set (+15 V and -15 V by default). So an inverting amplifier shows its inverting input a few microvolts from 0 V (the virtual ground, made visible), and the same amplifier driven too hard reads saturated, its inputs no longer equal. The 741-like model lowers the open-loop gain to 2×105 and adds a 1 MHz gain-bandwidth limit and 75 Ω of output resistance, so its answers drift from the textbook's as the frequency rises. There is no input offset, bias current or slew rate. The table is exact for this model at DC, and at AC as long as no op-amp output crosses a limit during the cycle; when one would, or when a circuit oscillates by itself, such as a relaxation oscillator or a Wien bridge with too much gain, the table says so instead of showing numbers. The scope simulates op-amp circuits too, switching each output between its limits at the instant its input crosses the threshold, so it shows clipping, comparators, Schmitt triggers and oscillators as they behave.
The Examples menu's Op-amps category opens eleven circuits drawn the textbook way. The first five are amplifiers the table solves outright; the other six are what the scope is for, and each opens with a note on what to look for: an integrator, with a resistor across its capacitor as the DC path a practical integrator needs (without it, any steady input winds the output up to a limit); a differentiator; a Sallen-Key active low-pass filter set to its corner frequency; a comparator and a Schmitt trigger switching on a 60 Hz sine; and a relaxation oscillator that runs with no source at all, its period 2RC ln 3 set by the capacitor charging toward each output limit in turn. All eleven use the Ideal model, which behaves like the textbook's ideal op-amp more than like any real part: it has no slew rate yet, so an output jumps from one limit to the other at once, where a 741 takes about 60 µs to swing 30 V, and its output limits are the only trace of a power supply.
Transformers join the same equations. Each winding adds one: its voltage is the core's voltage per turn times its turns, plus the drop in its own resistance and leakage reactance, and one more equation per core says the windings' ampere-turns add up to the current that magnetises it. The Ideal model keeps only the turns ratio; the Practical model takes its resistance, leakage and magnetising current from the nameplate figures you enter (%Z, X/R, the exciting current and the rated frequency), so regulation and fault current come out as a real transformer's would. A three-phase transformer is three single-phase units wired per its vector group, so Dyn1's 30 degree lag, Dyn11's lead and Dyn5's 150 degrees come from the connections, not from a formula. A three-phase source is three AC sources of one frequency, 120 degrees apart, in wye with its neutral or in delta. A transformer passes no DC: at DC each winding is just its resistance. On the scope, transformer circuits start in their AC steady state, because a real core's magnetising current would otherwise take seconds to settle.
The Power examples, the Examples menu's Transformers, Three-phase systems, Three-phase transformers and Home wiring and safety categories, open thirty-seven transformer and three-phase circuits. Under Transformers, a 10 : 1 step-down with a load, a 12-0-12 V centre-tapped supply at 50 Hz, impedance matching to a speaker, a boost autotransformer, DC on a winding, and the regulation and available fault current of a 25 kVA distribution transformer; under Three-phase systems, balanced three-phase loads in wye and in delta, a wye and a delta load drawing the same line currents, the per-phase equivalent, three-phase power read the way two wattmeters read it, power factor correction with a capacitor bank, the neutral current of a 480Y/277 V panel, an unbalanced delta, a 240 V heater on a 208 V supply, the voltage drop on a long feeder, a ground fault on an ungrounded delta and a six-pulse rectifier; under Three-phase transformers, a phase-sequence indicator, a 480 V to 208Y/120 V delta-wye bank with its 30 degree shift, the same bank unbalanced, Dyn1 and Dyn11 banks side by side, wye-wye banks with the primary star grounded and floating, an open delta, a corner-grounded delta and distribution transformers from India (Dyn11, 50 Hz) and Colombia (Dyn5). Under Home wiring and safety, beside the open-neutral demo, the forensic cases: a 120/240 V split-phase service from a 7.2 kV line, with the reason a generator must never be connected without a transfer switch (it backfeeds the line); an open neutral on that service and on a 208Y/120 V service, each with and without a ground rod; single phasing, a blown primary fuse that leaves one phase full and two at half, with unequal loads and on a lightly loaded bank; and a wild leg, the 208 V high leg of a 240/120 V delta, feeding a 120 V heater. They are the failures our forensic electrical engineers investigate when appliances burn out on one leg of a house or a motor burns out on a lost phase.
Diodes and transistors make the equations nonlinear, so the solver finds their answer by Newton's method: it guesses, straightens each device's curve at the guess, solves, and repeats until every current agrees, usually in under ten rounds. With an AC source it then finds the repeating waveform one cycle long and reports each part's true RMS, its average (the DC value), the true RMS of its AC part (what a meter set to AC reads) and the component at the source frequency with its angle, so a rectifier's DC output and its ripple both appear in the table. A circuit with two stable states, such as a latch, is flagged when the solver lands between them. Circuits that switch on their own, like a transistor flasher, have no steady answer: the table says so, and in this version the scope follows them only up to their first switching edge. When the solver cannot settle on an answer, it says so and shows no numbers.
The Examples menu's Diodes and LEDs and Transistors categories open twenty-one circuits, each with a note on what to notice: an LED and its resistor, an LED dimmer on a potentiometer, an LED driven by a current source, a diode's curve and load line, half-wave and bridge rectifiers with and without a filter capacitor (their ripple factors included), a Zener regulator, a clipper and a clamper; then a transistor switch, a common-emitter amplifier and the same kind of stage drawn on a VCC supply rail, an emitter follower, a current mirror, the same mirror with emitter resistors and a Wilson mirror (each copying its current more closely), a MOSFET switching a coil with its flyback diode, a common-source amplifier and a CMOS inverter. The parts are typical ones from published data: 1N4148, 1N4001, 1N4007 and 1N5819 diodes, LEDs in six colours, 1N4733A and 1N4742A Zeners, 2N3904, BC547B and 2N3906 bipolar transistors, and 2N7000, FQP30N06L, IRLZ44N, IRF520, IRFZ44N and BS250 MOSFETs, each with a Custom choice for your own values.
Logic parts work by events instead of equations. Gates, flip-flops, counters and the other blocks pass 0s and 1s, and the simulator works out each change and when it happens: every part has one propagation delay (10 ns for a gate and 15 ns for a flip-flop or block, typical 74HC values, unless you change them), so a change travels through a circuit one delay per part, and a glitch or a ripple shows where the textbook says it should. An input nothing drives, two outputs fighting, a setup time missed or a latch released into a race read X, unknown, with a note saying why. Where a logic output meets a resistor, an LED or a transistor, it is its family’s supply behind a typical output resistance, and a logic input reads its node’s voltage against a switching point, so a gate driving an LED draws a real current and a slowly rising input switches a gate at the right moment. The table shows each part’s level, and a truth table under it for a circuit without memory; the Scope tab shows a timing diagram with labelled lanes, cursors and zoom down to 1 ns.
The Examples menu’s Digital logic and Sequential logic categories open sixteen circuits: seven gates on two switches, a gate driving an LED, a CMOS inverter beside a logic NOT, a NAND gate edited as its own transistors, half and full adders, a multiplexer with its glitch and the extra gate that removes it, and a 7-segment decoder; then an SR latch and its race, a D flip-flop dividing by two, a setup-time violation, ripple and decade counters with a display, a shift register and a ring oscillator. DigiMin, the logic minimizer in its own tab, takes a function of 2 to 6 variables as a truth table, minterms and don’t-cares, or a Boolean expression, and gives its minimal sum of products and product of sums (Quine-McCluskey, with Petrick’s method for an exact minimum and every minimal cover when there are several), a Karnaugh map with the groups drawn, the prime and essential prime implicants, the steps, and NAND-only and NOR-only forms. Build on the canvas draws the minimal circuit and checks it against the truth table, and From the canvas reads the truth table of a circuit you drew.
The Instrumentation category opens a 4-20 mA current loop, the industrial way to send a sensor's reading down a long pair of wires: a two-wire transmitter drawn out from an op-amp, a MOSFET and a current mirror with a gain of 100, round a 24 V loop into a 250 Ω receiver, at 50%, at 0% (the 4 mA live zero), at 100% and with a broken wire.
Using It as a Thévenin Equivalent Calculator
The Thévenin tool on the canvas performs one more trick from the standard toolbox: pick any two nodes and the solver collapses the whole network between them into a single equivalent source Vth and resistance Rth. Vth is the open-circuit voltage between the nodes, and Rth comes from zeroing every source and injecting a test current, the same procedure taught in every circuits course and used daily to reason about what a network looks like from its terminals. Beside it the tab draws the Norton equivalent, a current source In = Vth / Rth with the same resistance across it, and Build it draws either one into your circuit.
With an AC source, the solver works in the phasor domain and reports RMS values, the effective values that make power calculations come out the same as DC. A purely resistive circuit keeps current in phase with voltage (power factor 1), so frequency changes nothing. Add a capacitor or an inductor and that stops being true: the solver switches to complex impedances automatically (1/jωC and jωL at the source's frequency), current magnitudes start depending on frequency, and at DC the same parts become open and short circuits, which is sinusoidal steady-state analysis exactly as the second circuits course teaches it. Try the RC filter example at its corner frequency, where the capacitor voltage lands at the source voltage divided by √2. Each AC source also has its own frequency and its own phase angle, 0° unless you set one: two 120 V sources at one frequency, half a cycle apart (0° and 180°), like the two legs of a split-phase service, put 240 V between their outer ends. Sources at different frequencies are solved one frequency at a time, each time with only the sources at that frequency active, and the table superposes the phasor solutions, their RMS values adding in quadrature: in the example of two frequencies into an RC low-pass, the capacitor keeps most of a 60 Hz source and little of a 5 kHz one. That jump from real resistance to complex impedance is part of why students ask whether electrical engineering is hard.
The scope under the canvas runs a genuine transient simulation, trapezoidal integration of the same companion models professional simulators use: capacitors charge along real exponentials (the Capacitors and inductors example that charges a capacitor and flashes an LED shows one), inductors resist changes in current, AC circuits visibly settle into steady state from t = 0, and switches or the sources themselves can be scheduled to flip at chosen times. Interrupting an inductor's current shows the voltage kick that makes switch contacts arc: with a resistor or a capacitor across the inductor the scope resolves the spike to the same height in any time window, and where nothing else can carry the current (ideal parts then make the spike unbounded) it labels the spike instead of drawing a number.
Where This Math Goes to Work
These are not classroom-only relationships. A failed neutral turns a house's two 120 V legs into one series circuit across 240 V, and voltage division decides which outlets see the overvoltage. Try the open-neutral demo to watch it happen in the simulator above. Our separate article covers how an open neutral shows up in a real house, from the first warning signs to who to call. An undersized resistor running past its power rating is a failure investigation waiting to happen. Our forensic electrical engineers use these same fundamentals, scaled up, in failure analysis, power studies, and expert witness work. If your problem needs an engineer rather than a simulator, contact our licensed Professional Engineers.
The same network equations, written for a whole building or plant, are the core of Dreiym's power system studies. Solved for a facility's transformers, cables and breakers with a fault applied, they give the current each protective device must interrupt, which is what a short circuit analysis checks against equipment ratings. That fault current and the time the protective devices take to clear it are the main inputs to an arc flash study, which labels each panel with the incident energy a worker could face. Grounding is Ohm's law at earth scale: the resistance from a ground electrode to remote earth, times the fault current flowing into it, is how far the ground voltage rises, and our grounding system tests measure that resistance.
Accuracy and Limits
Every update of the solver is checked against reference solvers written separately in Python® (numpy), which share no code with it. On the current version:
- DC and AC results. On 1,000 randomly generated drawings of resistors, capacitors, inductors, switches and DC or AC sources with everyday values (1 Ω to 1 MΩ, 1 nF to 100 µF, 1 mH to 10 H, up to 100 V, 10 Hz to 10 kHz), every voltage and current at least 1% of the largest of its kind in its circuit agreed with the reference to within 0.001%. The drawings held 532 loops of ideal parts with a source in them (in 442 of the drawings), such as a source shorted by a closed switch or two voltage sources wired in parallel, which have no single valid answer: every one was flagged instead of solved, and only the circuit containing it was left unsolved. Loops of closed switches, or of inductors at DC, with no source in them (12 in the drawings) are solved: ideal parts leave the split of current around such a loop open, and the tool splits it by a fixed rule (closed switches in parallel share it equally, inductors share it as they would after starting from rest, which for two in parallel is in inverse proportion to their inductance, and a closed switch across an inductor carries all of it).
- Thévenin and Norton equivalents. On 132 random DC and AC networks, the equivalents agreed with the reference to within one part in a million: Rth and Zth of their own value, Vth of the largest source voltage.
- Op-amp circuits. On 300 randomly generated circuits of one to three op-amps working inside their output limits (DC, AC and both, open-loop gains from 102 to 107, with and without a bandwidth limit and output resistance), every voltage and current at least 1% of the largest of its kind in its circuit agreed with the reference to within 0.001%. On 90 more, driven past an output limit or wired with positive feedback, every op-amp settled in the state the reference found (the high one where two are stable), and wherever the table showed numbers they agreed to within the same 0.001%.
- Transformers and three-phase circuits. On 300 randomly generated circuits with one or two single-phase or centre-tapped transformers, Ideal and Practical, driven by DC, AC or both at 50, 60 and 400 Hz, every voltage and current agreed with a separately written reference to within one part in 108 of the largest in its circuit; and eight textbook and field cases, from a 10:1 step-down to an open neutral on a split-phase service, match their closed forms. On 300 more randomly generated circuits with one to three transformers of every kind and vector group, at 50 and 60 Hz, every voltage and current agreed with a separately written reference, which works out each vector group's wiring from its name, to within one part in 108; the ten vector groups give their textbook phase shifts; and all twenty textbook and field cases, from a 10:1 step-down to single phasing and a high-leg delta, match their closed forms.
- Diode and transistor circuits. On 300 randomly generated circuits of resistors, sources, diodes, LEDs, Zeners and transistors, every one was solved, and the currents balanced at every node to within 0.001% of the current through it, or 1 nA (an independent check). The operating points of the examples agree with separately written reference solutions to within one part in a million, and the averages and ripple of the half-wave and bridge rectifiers agree with an independent integration to within 0.02% and 1%.
- The scope. On 48 random networks (648 traces) and on textbook RC, RL, series RLC (underdamped, critically damped and overdamped) and AC circuits, every trace stayed within 0.5% of the exact solution after the first millisecond, and within 1.5% during it, measured against the trace's peak value.
- Logic circuits. On 300 randomly generated combinational and 100 sequential circuits, every level at rest, every truth table and every change in time agreed with a separately written reference simulator, to the picosecond. DigiMin’s minimal forms agreed with an exhaustive search on every function of 2 and 3 variables (6,642, don’t-cares included) and on 1,000 random functions of 4, and with the reference on 600 random functions of 5 and 6.
- The results table shows three significant figures.
What it does not model:
- Parts. Linear resistors, potentiometers, capacitors and inductors, ideal switches, changeover switches and push buttons, ideal DC and AC voltage sources, pulse and piecewise sources, controlled sources (VCVS, VCCS, CCVS and CCCS), op-amps, diodes, LEDs, Zener diodes, bipolar transistors, MOSFETs, transformers (single-phase, centre-tapped and three-phase), three-phase sources and complex loads (single-phase and three-phase), DC machines, three-phase induction motors and synchronous machines, and a ground symbol only, with the logic parts below, up to 750 parts per circuit (counting the parts inside the parts you make). Apart from the op-amp model, the Practical transformer and the semiconductors below, every part is ideal: no wire or source resistance, no parasitics, no tolerance or temperature effects; the machines below have their own.
- Op-amps. One adjustable model, not catalogue parts: a finite-gain amplifier (open-loop gain 106 unless you change it, with an optional gain-bandwidth limit and output resistance) whose output, measured from ground, stops at the output limits you set. It has no supply pins, input offset, bias current, slew rate or output current limit. When an output would cross a limit during the AC cycle, or the circuit oscillates by itself, the table says so instead of showing numbers, and the scope shows the waveform. The scope counts a circuit as oscillating only when its time window holds at least two switches in its second half: in a window too short for a slow oscillator, the table shows its unstable balance point instead.
- Transformers. Linear cores: no saturation, so no inrush current, no DC saturation and no ferroresonance, which matters most with one primary phase open and little load, where a real transformer can reach several times normal voltage (never read a low value here as safe); no core loss (the exciting current you set is purely magnetising); no winding capacitance or surges, so a switch that opens while a winding carries current shows the full voltage its leakage inductance drives into the rest of the circuit, where a real switch arcs until the current passes zero; no tap changer (edit the ratio instead); no temperature or thermal limit (loading is a steady-state percentage of the kVA rating). The percentages hold at the rated frequency; a real core run below it saturates. A three-phase transformer is three separate single-phase units, a bank: a three-legged core couples its phases in ways this does not show, which matters most for ungrounded wye primaries and their line-to-ground faults. Practical values are typical, not a specific unit's; small transformers have far more impedance and magnetising current than distribution units. Fault currents are bolted values from the nameplate %Z, which has a tolerance, with an ideal source behind the transformer unless you draw the source's impedance: this is not a short-circuit or arc flash study. There are no three-phase motor models: after a primary phase is lost, a running three-phase motor keeps its voltages far more balanced than resistive loads show, but one line carries about twice the current of the others. A DC step on a winding shows on the secondary until the flux settles; a real core saturates within tens of milliseconds and ends it sooner.
- Diodes, LEDs and transistors are typical parts at 27 °C built from published data: diodes and LEDs as exponential junctions with series resistance, Zeners with a breakdown knee, bipolar transistors with a fixed current gain and the Early effect, MOSFETs with the square law and no subthreshold current. Real parts vary a lot from one to the next (a 2N7000's threshold anywhere from 0.8 to 3 V; a white LED's forward voltage from 2.8 to 4 V). Their stored charge (junction capacitance and transit time from the published models, constant capacitances in MOSFETs) acts only on the scope, in time windows under 5 ms, where it sets a logic gate's delay and a diode's reverse recovery; the table, the Thévenin tool and longer windows leave it out, so nothing models a transistor amplifier's high-frequency roll-off; they do not heat up, and they are flagged, not destroyed, past their ratings. Reverse breakdown is modelled only in Zeners: a coil switched off with no flyback diode gives a spike the scope labels instead of drawing. A circuit with two stable states is flagged when the solver lands between them; otherwise the table shows one of them. In this version the scope follows a circuit that switches on its own (a transistor flasher) only up to its first switching edge, the Thévenin tool does not probe a circuit with a diode or transistor, and the table does not show the steady state of one driven by AC that also holds an op-amp, a transformer or a three-phase source: each says so, and the scope still runs them. The op-amp is modeled as a whole amplifier, not built up from transistors.
- DC machines (permanent-magnet, separately excited, shunt and series) are the linear models of a first machines course: no saturation, so a self-excited generator cannot build up and a series motor's torque keeps rising with the square of its current; no armature reaction, commutation or compound windings; friction and windage are the only rotational loss. The scope starts a machine circuit in its steady state at t = 0: put a switch in its supply to see it start.
- Induction motors are the per-phase equivalent circuit of a first machines course, with a forward and a backward field, so an unbalanced supply or a lost phase is solved for its average torque and its currents. They are solved at steady state only: the scope draws the steady state and leaves out a circuit switched while one runs, with no run-up. There is no saturation, and the rotor is a single cage, so a real design B motor's starting torque reads low; the torque pulsation of an unbalanced supply is left out.
- Synchronous machines are the round-rotor machine of a first machines course: per phase an EMF behind the synchronous impedance, its size set by the field current on the open-circuit characteristic's air-gap line, as a motor or a generator on a three-phase supply that sets its frequency. They are solved at steady state, at synchronous speed, with the power angle that carries the shaft's power; a demand past the pull-out power is refused, as a real machine would slip poles. Left out: salient poles (no reluctance torque), saturation (an overexcited machine needs more field current than shown), excitation limits, the swing and hunting after a change, the rotor heating of an unbalanced supply, and a generator running alone with its own load. Their efficiency counts the armature's copper loss and the friction and windage entered, not core, stray or field losses, so it reads high; enter core and stray losses under Friction and windage to include them.
- Logic parts. Gates, flip-flops, latches, counters, a shift register, adders, multiplexers, decoders, a 7-segment display, and logic switches, push buttons, clocks, probes and LED indicators, in four families (74HC, 74HCT, 74LVC and 74LS) with typical values, not catalogue parts: one propagation delay per part, no rise or fall times, inputs that draw no current, outputs a supply behind a typical resistance. An undriven input, contention, a missed setup or hold time, a race and a released preset and clear read X, where a real circuit settles to 0 or 1 at random. DigiMin is exact up to 6 variables; past its work limit it shows the cover it has found so far and says it is not proven minimal.
- Sine-wave sources, each at its own frequency. Each AC source has its own frequency, from 1 Hz to 100 kHz, and its own phase angle (0° unless you set one). AC is solved at one frequency at a time, with only the sources at that frequency active, and the table superposes one phasor solution per frequency: a voltage or current is the RMS total of its DC part and its part at each frequency, which add in quadrature because sine waves at different frequencies are orthogonal. A phase angle compares only with angles at the same frequency. In the same way, a three-phase source's three phases share its frequency and sit 120 degrees apart. Other waveforms (square, pulse) are not modelled.
- Frequency sweep plays one AC source across a range of frequencies with the other AC sources off. For resistors, capacitors, inductors, transformers and op-amps it is exact, the table's own phasor solve repeated at each frequency; for diodes and transistors it is small-signal at the DC operating point, with no transistor capacitances, so an amplifier's plot has no upper cutoff, and it is refused when the devices change state over the AC cycle.
- Floating points. A point that nothing ties to a source, such as one cut off by an open switch (at DC or at AC), has no defined voltage: the table shows a dash there. Capacitors cut off at DC read the voltages they reach charging from rest, so two in series share a DC source's voltage in inverse proportion to their capacitance, as the scope shows. On the scope an open switch is 1 GΩ rather than an ideal open, so a small capacitor behind one charges slowly through it there (1 nF on 12 V: about 1 V in 100 ms, 10 V in 2 s), while the table keeps the ideal open's 0 V. An op-amp input fed only through a capacitor is held at 0 V by a tiny leak (1 TΩ) to ground; no other node has one, so a 999 MΩ resistor hanging off a 120 V node reads 0 V, circuits of hundreds of megohms or picofarad capacitors at a few hertz are solved like any other, and a current that should be exactly zero reads 0 or, from rounding alone, under a picoamp (in our random-circuit checks).
- Ideal resonance. An inductor and a capacitor with no resistance in their loop, driven at exactly their resonant frequency, have no finite answer: the table names them instead of showing a number. Just off that frequency the ideal answer is finite but can be huge: 10 V on 1 H and 1 µF at 159.15494 Hz drives 257 kA.
- The scope starts from rest and picks its time step from the time window, the fastest AC source frequency and the circuit's own time constants and resonances (about 40 steps per cycle of ringing), with shorter steps right after every switching event. When ringing is too fast to follow for the whole window, the scope shortens the window, never below 5 ms, and says so; ringing too fast even for that is flagged, not resolved. When a switch breaks an inductor's only current path, ideal parts give the spike no finite height, so the scope labels it instead of drawing one. Transformer circuits start in their AC steady state instead of from rest, and a switch that interrupts a transformer winding's current is labelled like an inductor's kick.
It is an educational tool: results are for learning and checking coursework, not for design, safety or loss assessment.
Coming from Multisim Live?
Digilent® retired Multisim® Live, its browser-based circuit simulator, on September 15, 2026. If you used it for circuits of resistors, capacitors, inductors and switches driven by DC or sine-wave AC voltage sources (each source at its own frequency and phase angle), this solver covers that work in any modern browser, free and without an account, and its op-amp model covers amplifier circuits at DC and AC and on the scope; transformers, including three-phase banks with their vector group, three-phase sources and complex loads are covered too, and so are diodes, LEDs, Zeners, bipolar transistors and MOSFETs, and logic gates, flip-flops and counters with a timing diagram, and a sweep of one AC source across frequencies (a Bode plot), and DC motors and generators, three-phase induction motors and synchronous machines, and DC and AC current sources, and pulse and piecewise sources and controlled sources, with a DC sweep of any part value and the stepping of one value. It does not replace everything Multisim did: there are no part models beyond these typical ones, no op-amp part models (one adjustable op-amp), and it cannot open Multisim files, so a circuit saved only as one has to be redrawn here. A SPICE netlist is different: Open circuit file (or Paste a netlist in the File menu) reads the netlists that Multisim, LTspice® and KiCad® export, in your browser, and draws the circuit for you. What you draw stays with you, as a link or a .json file.
Compare this simulator with Multisim Live and see how to bring a circuit across.
Frequently Asked Questions
Is the circuit simulator free?
Yes. It is free to use, with no account, no sign-up and nothing to install: it opens in your web browser, and our server does the calculations. A circuit can hold up to 750 parts.
Does it do AC and transient analysis?
Yes. DC circuits are solved directly, and AC circuits are solved as phasors: each AC source has its own frequency between 1 Hz and 100 kHz and its own phase angle, and the table superposes one phasor solution per frequency, with voltages and currents shown as RMS values and their phase angles; with DC and AC sources together, the table shows the combined RMS value and, under it, the DC part and the AC part with its angle, and with sources at several frequencies, the value at each frequency with its angle. The scope under the drawing runs a transient simulation from rest, so you can watch capacitors charge, inductors resist changes in current, AC circuits settle, and switches or sources turn on and off at times you choose. Op-amp circuits run on the scope too, clipping and switching included. Circuits with diodes or transistors driven by AC show their steady repeating waveform in the table, as its average, the true RMS of its AC part and the component at the source frequency, and circuits that oscillate on their own are shown on the scope, which in this version follows one that switches suddenly (a transistor flasher) only up to its first switching edge.
Can it draw a Bode plot (frequency response)?
Yes. The Sweep tab plays one AC source from a low to a high frequency and plots the gain in dB and the phase against a log frequency axis, with the -3 dB points, a resonance's peak, Q and bandwidth, and a notch marked. Settings picks the source, the range, the points per decade and up to four voltages or currents; Save gives the plot as PNG or SVG and the points as CSV. The settings travel in the share link.
Can it do transformers and three-phase circuits?
Yes: single-phase and centre-tapped transformers, as an Ideal turns ratio or a Practical model built from the nameplate (%Z, X/R, the exciting current and the rated frequency), with its regulation, its losses and the fault current at its terminals; three-phase transformers in ten vector groups (Dyn1, Dyn11, Dyn5, YNyn0, Yyn0, Dd0, YNd1, Yd1, YNd11, Yd11); and three-phase sources in wye or delta, ABC or ACB. The examples include a 120/240 V service from a 7.2 kV line, a 480 V to 208Y/120 V delta-wye bank, open delta and high-leg delta banks, an open neutral on a split-phase and a 208Y/120 V service, and the loss of one primary phase.
Does it simulate diodes and transistors?
Yes: diodes, LEDs, Zener diodes, NPN and PNP bipolar transistors and N- and P-channel MOSFETs, each a typical part from published data or your own Custom values, solved by Newton's method. DC circuits show each device's operating point with its state (an LED lit, a Zener regulating, a transistor saturated or active); a circuit driven by AC shows its repeating waveform's average, the true RMS of its AC part, which is what a meter set to AC reads, and the component at the source frequency. Their stored charge acts only on the scope, in time windows under 5 ms, where a logic gate shows its delay, and real parts vary from one to the next; Accuracy and Limits above lists what is not modelled.
Can it simulate motors and generators?
DC machines, three-phase induction motors and synchronous machines, yes. DC machines: permanent-magnet, separately excited, shunt and series motors and generators, each with its armature, field and shaft; the table gives the operating point (speed, torque, currents, efficiency), the scope follows a start or a load step, and Machine charts, from the selected machine, draws its speed against torque and lists its power flow. Induction motors: the slip on any three-phase supply, as a motor, a generator above synchronous speed or held at standstill, with the torque against speed and the power flow under Machine charts. Synchronous machines: a motor or a generator on a three-phase supply, set by its shaft power and field current, with its power angle, power factor (leading or lagging) and pull-out power, and the power-angle curve, V-curves and phasor diagram under Machine charts. The models are linear (no saturation) and the AC machines are solved at steady state only; salient poles and a machine's swing after a change are not in this version.
Can it simulate logic gates and flip-flops?
Yes: AND, OR, NAND, NOR, XOR and XNOR gates with 2 to 4 inputs, NOT and buffer gates, SR and D latches, D, JK and T flip-flops with clock edges, preset and clear, half and full adders, multiplexers, decoders, a 7-segment decoder and display, a counter and a shift register, driven by logic switches, push buttons and clocks and read by logic probes and LED indicators. The table shows each level and, for a circuit without memory, its truth table; the Scope tab shows a timing diagram. Logic and analog parts can share a circuit, such as a gate lighting an LED through a resistor.
What is DigiMin?
The logic minimizer in the simulator’s DigiMin tab. Give it a function of 2 to 6 variables as a truth table, minterms and don’t-cares, or a Boolean expression, and it gives the minimal sum of products and product of sums, every minimal cover when there are several, a Karnaugh map with the groups drawn, the prime implicants, the steps, and NAND-only and NOR-only forms. Build on the canvas draws the circuit and checks it against the truth table.
How are logic levels and delays modelled?
Each part has one propagation delay, 10 ns for a gate and 15 ns for a flip-flop or block by default, and a pulse shorter than a delay does not get through. Levels are 0, 1 and X (unknown), with a logic family’s thresholds where a logic input reads an analog voltage, such as 1.5 V and 3.5 V for 74HC at 5 V, and a reading between them is flagged as inside the forbidden band. There are no rise or fall times; Accuracy and Limits above lists the rest.
My textbook says vi = 5 sin ωt: what do I type?
5 V is the peak, and the AC source's value is RMS, so type 3.536 (5 divided by √2). The source shows the peak under its value as you type, and every example with an AC source gives both, such as 3.536 V RMS = 5 V peak.
How do I find a Thévenin or Norton equivalent?
Pick the Thévenin tool and click two terminal dots: the first sets probe A, the second probe B. You can also right-click a terminal dot and choose Set Thévenin probe A or Set Thévenin probe B. The line above the drawing shows Vth and Rth, or Zth as R + jX with its magnitude and angle when capacitors or inductors are involved, and under the drawing it adds the Norton current In = Vth / Zth and the load that would take the most power. The probed parts stay in the circuit, so for the textbook equivalent seen by a load, delete the load first and probe the two nodes it was connected to.
How do I share or save a circuit?
Copy link copies a link that holds the whole circuit; whoever opens it gets their own editable copy. Save circuit (.json) downloads the circuit as a small file you can keep, email or hand in, and Open circuit file loads one back. PNG image and SVG file save a picture of the schematic, and the scope has its own Save PNG. Your last circuit is also kept in your browser automatically, and the page offers Restore your last circuit when you come back.
Where is my circuit calculated?
On our secure calculation server. To show results, the simulator sends your circuit there; it is used only to work out the answer and is not stored or logged. The first calculation runs a quick Cloudflare® check that you are a person. We keep a copy of your circuit only if you send us a message with Find a mistake or have a feature request? under the simulator: your circuit is attached to it. A shared link carries the circuit after the # sign (the URL fragment), which browsers do not send with the page request; when someone opens it, their copy is calculated on our server the same way. Autosave uses your browser's local storage, on your own device. The site's own analytics, hosted by Dreiym, counts events such as a copied link, never the circuit itself.
How accurate is it?
For the ideal parts it models, on our checks against independent reference solvers: across 1,000 random drawings with everyday values, every voltage and current at least 1% of the largest of its kind agreed to within 0.001%; on 132 random networks, Thévenin equivalents agreed to within one part in a million; and on the circuits we test, the scope stayed within 0.5% of each trace's peak after its first millisecond. Some cases are further off: ringing faster than the scope's time step is drawn wrong (the scope warns when that happens). And some have no single answer: a point that nothing ties to a source at DC shows a dash, and an inductor and a capacitor driven at exactly their resonant frequency are named instead of solved. Accuracy and Limits above gives the details and what the tool does not model.
Who built it?
Dreiym Engineering PLLC, an engineering firm whose licensed Professional Engineers work on electrical power studies, forensic electrical investigations and corrosion engineering. We wrote the solver from scratch, with no third-party code, and every update has to pass the checks against the independent reference solvers before it goes live.
More engineering tools
All calculatorsNeed an engineer, not a simulator?
We typically respond within one business day.